This course is designed to provide participants with a detailed and up-to-date overview of Locate Faults in Power System Underground Power Cables. It covers the power cable testing and construction; the cable pipe, joints, terminations and accessories for XLPE cables; the testing of distribution cables; the routine tests, special tests, type tests and site tests after installation; the high and extra high voltage testing, impulse voltage test and AC voltage test of the insulation; and the dielectric losses, cable measurements and loss measurement of dissipation factor.
Further, the course will also discuss the analysis of cable measurements results and the three-conductor cable insulation diagram; the partial discharge techniques and PD detection for cable diagnostics; the physical background of PD, types of partial discharge, characteristics of discharge patterns and breakdown cable voltage; the partial discharge test facility and test circuit inside shielded room; the calibration of partial discharge system; and the measurement of partial discharge.
During this interactive course, participants will learn the PD measurement methods available and the importance of PD for insulation of oil XLPE cables; the standard for onsite testing; the principle of VLF generator; the dissipation factor and measurements based on XLPE; the water treeing in polymeric insulation and comparison of electrical treeing and water treeing; the comparison of channel growth; the simplified dielectric equivalent circuit of new cables and the application of VLF / PD diagnosis; tracing of cable fault location, PD tracks in slip joins for cables and cable fault types; the methods of cable fault location; the fault distance from cable end, bridge method (wheatstone) and cable tracing using cable locator; the acoustic fault location, propagation time measurement, audio frequency twist method and cable sheet fault location; the pin pointing set and cable test van, reduction of in-service cable failures, prioritization of cables in a cable replacement and development of a documented history of cable condition; and the cost reduction due to reduce in-services cable failures.
link to course overview PDF
Further, the course will also discuss the analysis of cable measurements results and the three-conductor cable insulation diagram; the partial discharge techniques and PD detection for cable diagnostics; the physical background of PD, types of partial discharge, characteristics of discharge patterns and breakdown cable voltage; the partial discharge test facility and test circuit inside shielded room; the calibration of partial discharge system; and the measurement of partial discharge.
During this interactive course, participants will learn the PD measurement methods available and the importance of PD for insulation of oil XLPE cables; the standard for onsite testing; the principle of VLF generator; the dissipation factor and measurements based on XLPE; the water treeing in polymeric insulation and comparison of electrical treeing and water treeing; the comparison of channel growth; the simplified dielectric equivalent circuit of new cables and the application of VLF / PD diagnosis; tracing of cable fault location, PD tracks in slip joins for cables and cable fault types; the methods of cable fault location; the fault distance from cable end, bridge method (wheatstone) and cable tracing using cable locator; the acoustic fault location, propagation time measurement, audio frequency twist method and cable sheet fault location; the pin pointing set and cable test van, reduction of in-service cable failures, prioritization of cables in a cable replacement and development of a documented history of cable condition; and the cost reduction due to reduce in-services cable failures.
TRAINING METHODOLOGY
This interactive training course includes the following training methodologies:
LecturesWorkshops & Work Presentations
Case Studies & Practical Exercises
Videos, Software & Simulators
In an unlikely event, the course instructor may modify the above training methodology for technical reasons.
VIRTUAL TRAINING (IF APPLICABLE)
If this course is delivered online as a Virtual Training, the following limitations will be applicable:
Certificates | : | Only soft copy certificates will be issued |
Training Materials | : | Only soft copy materials will be issued |
Training Methodology | : | 80% theory, 20% practical |
Training Program | : | 4 hours per day, from 09:30 to 13:30 |
RELATED COURSES
EE0275 : Electrical Protection
- Date: Nov 16 - Nov 20 / 3 Days
- Location: Dubai, UAE
- Course Details Register
EE0167 : Hazardous Area Classification & Intrinsic Safety
- Date: Nov 16 - Nov 20 / 3 Days
- Location: Doha, Qatar
- Course Details Register
EE0625 : High Voltage Electrical Safety (IEC/NFPA)
- Date: Nov 17 - Nov 21 / 3 Days
- Location: Abu Dhabi, UAE
- Course Details Register
EE0416-3D : Induction Motor & Its Control
- Date: Nov 16 - Nov 18 / 3 Days
- Location: Dubai, UAE
- Course Details Register